Executive Summary
1.4 Construction
Works Undertaken During the Reporting Period
2...... Air Quality Monitoring
4...... Water Quality Monitoring
6...... Environmental Site Inspection and Audit
6.2 Advice
on the Solid and Liquid Waste Management Status
6.3 Environmental
Licenses and Permits
6.4 Implementation
Status of Environmental Mitigation Measures
6.5 Summary
of Exceedance of the Environmental Quality Performance Limit
6.6 Summary
of Complaints, Notification of Summons and Successful Prosecution
7.1 Construction
Programme for the Coming Months
7.2 Environmental
Site Inspection and Monitoring Schedule for the Coming Month
Figures
Figure 2.1 Location
of Air Quality Monitoring Stations
Figure 3.1 Location
of Noise Monitoring Stations
Figure 4.1 Location
of Water Monitoring Stations
Figure 5.1 Impact
Dolphins Monitoring Line Transect Layout Map
Appendices
Appendix A Location
of Works Areas
Appendix B Project
Organization for Environmental Works
Appendix C Construction
Programme
Appendix D Event
and Action Plan
Appendix E Waste
Flow Table
Appendix F Environmental
Licenses and Permits
Appendix G Implementation
Schedule for Environmental Mitigation Measures (EMIS)
Appendix H Statistics
on Environmental Complaints, Notification of Summons and Successful
Prosecutions
Appendix I Environmental
Site Inspection and Monitoring Schedule
Executive Summary
This
monthly Environmental Monitoring and Audit (EM&A) Report is prepared for
Contract HY/2013/01 Hong Kong-Zhuhai-Macao Bridge Hong Kong Boundary Crossing
Facilities (HKBCF) –
Passenger Clearance Building (hereafter referred to as “the Contract”) for the
Highways Department of Hong Kong Special Administrative Region (HKSAR). The
Contract was awarded to Leighton – Chun Wo Joint Venture (hereafter referred to
as “the Contractor”) and Atkins China Limited was appointed as the
Environmental Team (ET) by the Contractor.
The
Contract is part of Hong Kong – Zhuhai – Macao Bridge HKBCF which is a “Designated
Project”, under Schedule 2 of the Environmental Impact Assessment Ordinance
(EIAO) (Cap 499) and Environmental Impact Assessment (EIA) Report (Register No.
AEIAR-145/2009) was
prepared for the Project. The current Environmental Permit (EP) No. EP-353/2009/K
for HKBCF was
issued on 11 April 2016. These documents are available through the EIA
Ordinance Register. Site preparation works of the
Contract started on 26 September 2014 and the construction works of
the Contract
commenced on 6 October 2014.
Atkins
China Limited has been appointed by the Contractor to implement the
Environmental Monitoring & Audit (EM&A) programme for the Contract in accordance
with the Updated EM&A Manual for HKBCF
(Version 1.0) and will be providing environmental team services to the
Contract.
This
is the thirty-fifth monthly EM&A Report for the Contract which summarizes
findings of the EM&A works during the reporting period from 1 to 31 August
2017.
Environmental Monitoring and Audit Progress
The
monthly EM&A programme was undertaken in accordance with the Updated EM&A
Manual for HKBCF (Version 1.0). It should be noted that the air quality,
noise, water quality and dolphin monitoring works for the Contract are covered by Contract No. HY/2010/02 Hong Kong-Zhuhai-Macao
Bridge HKBCF – Reclamation Works and Contract No. HY/2011/03 Hong
Kong-Zhuhai-Macao Bridge Hong Kong Link Road – Section between Scenic Hill
and HKBCF. The ET of the Contract or
another ET of the HZMB project is required to conduct impact air quality monitoring
at AMS6 and AMS7, noise monitoring at NMS2 and NMS3B, water quality monitoring
at twenty-one stations (nine Impact Stations, seven Sensitive Receiver Stations
and five Control/Far Field Stations) and dolphin monitoring works at twenty-four
transects as part of EM&A programme if these monitoring stations/transects are
no longer covered under Contract Nos. HY/2010/02 and HY/2011/03. However, this is subject to ENPO’s final
decision on which ET should carry out the monitoring work at these stations/transects.
The dates of site inspection during the reporting
period are
listed below:
Environmental
Site Inspection: 2,
9, 16, 25 and 30 August 2017
Breaches of Action and Limit Levels
Summary
of Action and Limit Level exceedance of 1-hr TSP level and 24-hr TSP level at
AMS6 shall be referred to the monthly EM&A report prepared by Contract No.
HY/2011/03.
There
was no Action and Limit Level exceedance of 1-hr TSP level and 24-hr TSP level
recorded at AMS7 by the Environmental Team of Contract No. HY/2010/02 during
the reporting period.
There
was no Action and Limit Level exceedance for noise recorded at NMS2 and NMS3B
by the Environmental Team of Contract No. HY/2010/02 during the reporting
period.
There
were no Action Level and Limit Level exceedance of Dissolved Oxygen (DO),
Turbidity and Suspended Solids (SS) recorded by the Environmental Team of Contract
No. HY/2010/02 during the reporting period.
Impact dolphin monitoring results at all transects are
reported in the EM&A Report prepared for Contract No. HY/2010/02.
Complaint Log
There
was no complaint received in relation to the environmental impact during the reporting
period.
Notifications of Summons and Successful
Prosecutions
There
was no notifications of summons or prosecutions received during the reporting
period.
Reporting Change
There
was no reporting change during the reporting period.
Future Key Issues
The
future key issues to be undertaken in the upcoming month include:
Land
Based work
·
Waterproofing
·
Backfilling
·
Formwork
and falsework stripping
·
Western
vertical column
·
Blockwork
walls
·
Pipework
and ductwork installation
·
Hanger
rods for cable container
·
Wet
trade works
·
Dry
trade works
·
Façade
Bracket for Cabins
·
Mechanical,
Electrical and Plumbing (MEP) High Level Containment
·
Removal of temporary
works
·
Window wall glazing
·
Heat exchanger
installation
·
Heavy MEP plant set up
in basement
·
Double Bow Truss
installation
·
Mullion Frame
Installation
·
Curtain wall glaring
·
Hanging scaffolding
·
Footbridge
construction
·
Roof cladding
·
Refuse collection
point
·
Southern toilet
·
Miscellaneous
steelwork
·
Lift installation
·
Escalator Installation
·
Glazed lift
Installation
·
Road and Kerbing
No
marine based construction work will be undertaken in the upcoming month.
·
Construction of Passenger Clearance Building
(PCB) including architectural and builders works, structural steel roof and
reinforced concrete frames, basement, piled foundations, aluminium roof,
curtain wall facades, building services and electrical and mechanical works;
·
Installation of district cooling system including seawater cooling intake pumping
station, seawater intake and discharge water pipelines work; Installation of
Chilled water cooling pipelines system, heat exchanger and chilled pumping
system;
·
Construction of transport and associated
facilities connecting to the PCB entailing the Emergency Vehicular Access, an
at-grade mainland side drop-off area, an Hong Kong side elevated drop-off deck
and 8 numbers of footbridge links;
·
Construction of a public toilet, 6 numbers of
C&ED observation booths, a generator set building and a refuse storage
& material recovery chamber;
·
Construction of a section of 70m common
utilities enclosure and staff subway and civil provisions for associated
electrical and mechanical works;
·
Construction of drainage, sewerage, fresh water
& flushing water supply and utilities & service works;
·
Construction of civil provisions, including
draw pits & ducting for Traffic Control and Surveillance System (TCSS) and
Extra Low Voltage System (ELV);
·
Construction of box culvert A;
·
Construction of 2 numbers of vehicular bridge
abutments at mainland side pickup area earthmound;
·
Construction of geotechnical works including
top up the existing earth mound from +11.5mPD to the finished level as stated
in the Contract, reinforced earth slope and fill slopes and special backdrop
manhole at mainland side pickup area earthmound;
·
Landscape hardworks and softworks; and
·
Other works which are shown on the Drawings or
specified in the Specification or which may be ordered in accordance with the
Contract.
Table
1‑1 Contact
Information of Key Personnel
Party |
Position |
Name |
Telephone |
Fax |
Engineer
or Engineer’s Representative |
Chief
Resident Engineer |
Michael
Tovey |
3958
7470 |
3468
2076 |
Environmental
Project Office / Independent Environmental Checker (Ramboll Environ Hong Kong
Limited) |
Environmental
Project Office Leader |
Y.
H. Hui |
3465
2888 |
3465
2899 |
Independent
Environmental Checker |
Raymond
Dai |
3465
2888 |
3465
2899 |
|
Contractor
|
Project
Manager |
Owen Leung |
9232
5750 |
3621
0180 |
Environmental
Officer |
Michael Lee |
9502 5887 |
3621
0180 |
|
Environmental
Team |
Environmental
Team Leader |
Keith
Chau |
2972 1721 |
2890
6343 |
24 hours
complaint hotline |
--- |
--- |
3958 7300 |
--- |
·
Waterproofing
·
Backfilling
·
Formwork and falsework stripping
·
Western vertical column
·
Blockwork walls
·
Pipework and ductwork installation
·
Hanger rods for cable container
·
Wet trade works
·
Dry trade works
·
Façade Bracket for Cabins
·
MEP High Level Containment
·
Trolley Removal Works
·
Removal of temporary works
·
Window wall
·
CLP 11KV installation
·
Pipework and duct work installation
·
Heat exchanger installation
·
District Cooling System (DCS) chilled water
pipe installation
·
Heavy MEP plant set up in basement
·
Box Culvert RC works
·
Double Bow Truss installation
·
Mullion Frame Installation
·
Curtain wall glaring
·
Window wall glaring
·
Hanging scaffolding
·
Footbridge construction
·
Roof cladding
·
Refuse collection point
·
Southern toilet
·
MISC steelwork
·
Lift installation
·
DCS outfall construction works
Table 2‑1 Construction
Dust Monitoring Locations
ID |
Location Description |
AMS 6(1) |
Dragonair/CNAC
(Group) Building |
AMS 7(1), (2) |
Hong
Kong SkyCity Marriott Hotel |
Remark:
(1)
The ET of
this Contract should conduct impact air quality monitoring at the AMS listed in
the table as part of EM&A programme according to the latest notification from ENPO when the monitoring
station(s) is/are no longer covered by another ET of the HZMB project.
(2)
The original
monitoring location was at Hong Kong SkyCity Marriott Hotel (AMS7). As the permission to carry out air
quality monitoring at Hong Kong SkyCity Marriott Hotel was not granted after 31
January 2015, the monitoring location was relocated to Chu Kong Air-Sea Union
Transportation Co. Ltd. (AMS7A) from 5 February 2015 to 30 December 2015. The alternative monitoring location at Chu
Kong Air-Sea Union Transportation Co. Ltd. was approved by EPD on 5 February
2015. However, AMS7A was
relocated back to its original location (AMS7-Hong Kong SkyCity Marriott Hotel)
on 30 December 2015. The relocation
of air quality monitoring location, AMS7A, back to AMS7 was approved by EPD on
21 December 2015.
Table 2‑2 Action
and Limit Levels for 1-hour TSP
Monitoring
Station |
Action
Level, µg/m3 |
Limit
Level, µg/m3 |
AMS
6 – Dragonair / CNAC (Group) Building (HKIA) |
360 |
500 |
AMS
7 - Hong Kong SkyCity
Marriott Hotel |
370 |
Table 2‑3 Action
and Limit Levels for 24-hour TSP
Monitoring
Station |
Action
Level, µg/m3 |
Limit
Level, µg/m3 |
AMS
6 – Dragonair / CNAC (Group) Building (HKIA) |
173 |
260 |
AMS
7 - Hong Kong SkyCity Marriott Hotel |
183 |
Table 3‑1 Construction
Noise Monitoring Locations
ID |
Location
Description |
NMS2(1) |
Seaview
Crescent |
NMS3B(1)(2) |
Site Boundary
of Site Office
Area at Works Area WA2 |
Remarks:
(1)
The ET of
this Contract should conduct impact noise monitoring at the NMS listed in the
table as part of EM&A programme according to the latest notification from ENPO when the monitoring
station(s) is/are no longer covered by another ET of the HZMB project.
(2)
The Action
and Limit Levels for schools will be applied for this alternative monitoring
location.
Table 3‑2 Action
and Limit Level for Construction Noise
Parameter |
Action Level |
Limit Level |
07:00 – 19:00 hours
on normal weekdays |
When one documented complaint is received |
75 dB(A)* |
Notes:
If works are to be carried out during restricted hours, the conditions stipulated in the construction noise permit issued by
the
Noise Control Authority have to be followed.
* Limit level is 70 dB(A) for
schools and 65 dB(A) during school examination period.
Table 4-1 Impact Water Quality Monitoring Stations
Station |
Description |
East |
North |
IS5 |
Impact Station
(Close to HKBCF construction site) |
811579 |
817106 |
IS(Mf)6 |
Impact Station
(Close to HKBCF construction site) |
812101 |
817873 |
IS7 |
Impact Station (Close
to HKBCF construction site) |
812244 |
818777 |
IS8 |
Impact Station
(Close to HKBCF construction site) |
814251 |
818412 |
IS(Mf)9 |
Impact Station
(Close to HKBCF construction site) |
813273 |
818850 |
IS10 |
Impact Station
(Close to HKBCF construction site) |
812577 |
820670 |
IS10(N)* |
Impact Station
(Close to HKBCF construction site) |
812942 |
820881 |
Impact
Station (Close to HKBCF construction site) |
813562 |
820716 |
|
Impact Station
(Close to HKBCF construction site) |
814328 |
819497 |
|
IS17 |
Impact Station
(Close to HKBCF construction site) |
814539 |
820391 |
SR3 |
Sensitive receivers
(San Tau SSSI) |
810525 |
816456 |
SR4(N) |
Sensitive receivers
(Tai Ho) |
814705 |
817859 |
SR5 |
Sensitive receivers
(Artificial Reef in NE Airport) |
811489 |
820455 |
SR5(N)* |
Sensitive receiver (Artificial
Reef in NE Airport) |
812569 |
821475 |
SR6 |
Sensitive receivers
(Sha Chau
and Lung Kwu Chau Marine Park) |
805837 |
821818 |
SR7 |
Sensitive receivers (Tai Mo Do) |
814293 |
821431 |
SR10A |
Sensitive receivers
(Ma Wan FCZ) 1 |
823741 |
823495 |
SR10B(N) |
Sensitive receivers
(Ma Wan FCZ) 2 |
823683 |
823187 |
CS(Mf)3 |
Control Station |
809989 |
821117 |
CS(Mf)3(N)* |
Control Station |
808814 |
822355 |
CS(Mf)5 |
Control Station |
817990 |
821129 |
CS4 |
Control Station |
810025 |
824004 |
CS6 |
Control Station |
817028 |
823992 |
CSA |
Control
Station |
818103 |
823064 |
Table
4-2 Action and Limit Levels for Water Quality
Parameters |
Action |
Limit |
DO in mg L-1 (Surface, Middle & Bottom) |
Surface and Middle |
|
SS in mg L-1 (depth-averaged) at all
monitoring stations and control stations |
23.5 and 120% of upstream control station's SS at the same tide of the
same day* |
34.4 and 130% of upstream control station's SS at the same tide of the
same day and 10mg/L for WSD Seawater intakes* |
27.5 and 120% of upstream control station's turbidity at the same tide
of the same day* |
47.0 and 130% of upstream control
station's turbidity at the same tide of the same day* |
Table
5-1 Impact
Dolphin Monitoring Line Transect Co-ordinates (Provided by AFCD)
Transect ID |
HK Grid System |
Long Lat in WGS84 |
||
X |
Y |
Long |
Lat |
|
1* |
804671 |
815456 |
113.870287 |
22.277678 |
804671 |
831404 |
113.869975 |
22.421696 |
|
2 |
805476 |
820800 |
113.877995 |
22.325951 |
805476 |
826654 |
113.877882 |
22.378815 |
|
3 |
806464 |
821150 |
114.030267 |
22.196697 |
806464 |
822911 |
114.047344 |
22.196712 |
|
4 |
807518 |
821500 |
114.033651 |
22.206219 |
807518 |
829230 |
114.108618 |
22.206267 |
|
5 |
808504 |
821850 |
114.037037 |
22.215126 |
808504 |
828602 |
114.102523 |
22.215169 |
|
6 |
809490 |
822150 |
114.039938 |
22.224033 |
809490 |
825352 |
114.070995 |
22.224056 |
|
7 |
810499 |
822000 |
114.038474 |
22.233143 |
810499 |
824613 |
114.063820 |
22.233163 |
|
8* |
811508 |
821123 |
113.936539 |
22.328966 |
811508 |
824254 |
113.936486 |
22.357241 |
|
9* |
812516 |
821303 |
113.946320 |
22.330606 |
812516 |
824254 |
113.946279 |
22.357255 |
|
10* |
813525 |
820827 |
113.956112 |
22.326321 |
813525 |
824657 |
113.956066 |
22.360908 |
|
11# |
814556 |
818853 |
113.966155 |
22.304858 |
814556 |
820992 |
113.966125 |
22.327820 |
|
12 |
815542 |
818807 |
113.975726 |
22.308109 |
815542 |
824882 |
113.975647 |
22.362962 |
|
13 |
816506 |
819480 |
113.985072 |
22.314192 |
816506 |
824859 |
113.985005 |
22.362771 |
|
14 |
817537 |
820220 |
113.995070 |
22.320883 |
817537 |
824613 |
113.995018 |
22.360556 |
|
15 |
818568 |
820735 |
114.005071 |
22.325550 |
818568 |
824433 |
114.005030 |
22.358947 |
|
16 |
819532 |
821420 |
114.014420 |
22.331747 |
819532 |
824209 |
114.014390 |
22.356933 |
|
17 |
820451 |
822125 |
114.023333 |
22.338117 |
820451 |
823671 |
114.023317 |
22.352084 |
|
18 |
821504 |
822371 |
114.033556 |
22.340353 |
821504 |
823761 |
114.033544 |
22.352903 |
|
19 |
822513 |
823268 |
114.043340 |
22.348458 |
822513 |
824321 |
114.043331 |
22.357971 |
|
20 |
823477 |
823402 |
114.052695 |
22.349680 |
823477 |
824613 |
114.052686 |
22.360610 |
|
21 |
805476 |
827081 |
113.877878 |
22.382668 |
805476 |
830562 |
113.877811 |
22.414103 |
|
22 |
806464 |
824033 |
113.887520 |
22.355164 |
806464 |
829598 |
113.887416 |
22.405423 |
|
23 |
814559 |
821739 |
113.966142 |
22.334574 |
814559 |
824768 |
113.966101 |
22.361920 |
|
24 |
805476 |
815900 |
113.979368 |
22.187721 |
805476 |
819100 |
114.010398 |
22.187756 |
|
Remarks: (a)
* Due to
the presence of deployed silt curtain systems at the site boundaries of the Contract, some of the transect lines shown
in Figure 5.1 could not be fully surveyed during the regular survey. Transect
10 is reduced from 6.4km to approximately 3.6km in length due to the HKBCF construction
site. Therefore the total transect length for both NEL and NWL combined is reduced
to approximately 108km (b)
# Coordinates
for transect lines 1, 8, 9 and 11 have
been updated in respect to the Proposal for Alteration of Transect Line for Dolphin
Monitoring approved by EPD on 19 August 2015. (c)
The change
of transect lines 2, 3, 4, 5, 6 and 7 and new transect line 24 were justified
and verified by the ET Leader for Contract No. HY/2010/02 and the IEC
respectively on 24 March 2017 and it was approved by EPD on 12 May 2017. |
Table 5-2 Action
and Limit Levels for Chinese White Dolphin Monitoring - Approach to
Define Action Level (AL) and Limit Level (LL)
|
North Lantau Social Cluster |
|
|
NEL |
NWL |
Action Level |
(STG < 70% of baseline)
& (ANI < 70% of baseline) |
(STG < 70% of baseline)
& (ANI < 70% of baseline) |
Limit Level |
[(STG < 40% of
baseline) & (ANI < 40% of baseline)] AND [(STG < 40% of
baseline) & (ANI < 40% of baseline)] |
Table 5-3 Derived
Value of Action Level (AL) and Limit Level (LL) for Chinese White Dolphin
Monitoring
|
North Lantau Social Cluster |
|
|
NEL |
NWL |
Action Level |
(STG < 4.2) & (ANI < 15.5) |
(STG < 6.9) & (ANI < 31.3) |
Limit Level |
[(STG < 2.4) & (ANI <8.9)]
AND [ (STG < 3.9) & (ANI < 17.9)] |
Table 6-1 Summary
of Environmental Site Inspections
Date of Audit |
Observations |
Actions Taken by Contractor / Recommendation |
Date of Observations Closed |
26 July 2017 |
1. Chemical containers were found without drip tray at 1/F PCB building
Row 3. |
1. The chemical
containers were removed on 1/F PCB building Row 3. |
2 August 2017 |
2 August 2017 |
No particular environmental issue was recorded during the site inspection. |
Nil. |
Nil. |
9 August 2017 |
1. Chemical containers were found without proper chemical labels on 1/F
PCB building Row 4. |
1. The chemical
containers were removed on 1/F of PCB building Row 4. |
16 August 2017 |
16 August 2017 |
1. More than 20 bags of dusty material were found without cover on 1/F
of PCB building Row 3. |
1. The bags of
dusty material were removed on 1/F of PCB building Row 3. |
25 August 2017 |
25 August 2017 |
1. Discoloured NRMM label affixed onto a generator in the vicinity of
box culvert area was observed. 2. Discoloured NRMM label affixed onto a generator in the vicinity of
seawater intake area was observed. |
1. An appropriate
NRMM label was affixed to the generator at the vicinity of box culvert area. 2. An appropriate
NRMM label was affixed to the generator at the vicinity of seawater intake
area. |
30 August 2017 |
30 August 2017 |
1. Chemical containers were observed without proper labels. A chemical
container was observed without drip tray. |
1. The Contractor
was remined to provide proper labels for the chemical containers and provide
drip tray for the chemical container. |
Follow-up action undertaken by the Contractor will be inspected during
the site inspection to be undertaken in September 2017. |
Table 7-1 Construction
Activities for September 2017
Site Area |
Description
of Activities |
Nature of
Activities |
WA1 |
Waterproofing
|
Land-Based |
WA1 |
Backfilling
|
Land-Based |
WA1 |
Formwork
and falsework stripping |
Land-Based |
WA1 |
Western
vertical column |
Land-Based |
WA1 |
Blockwork walls |
Land-Based |
WA1 |
Pipework and ductwork
installation |
Land-Based |
WA1 |
Hanger rods for cable container |
Land-Based |
WA1 |
Wet trade works |
Land-Based |
WA1 |
Dry trade works |
Land-Based |
WA1 |
Façade Bracket for Cabins |
Land-Based |
WA1 |
MEP High
Level Containment |
Land-Based |
WA1 |
Removal of temporary works |
Land-Based |
WA1 |
Window wall glazing |
Land-Based |
WA1 |
Heat
exchanger installation |
Land-Based |
WA1 |
Heavy MEP
plant set up in basement |
Land-Based |
WA1 |
Double
Bow Truss installation |
Land-Based |
WA1 |
Mullion
Frame Installation |
Land-Based |
WA1 |
Curtain
wall glaring |
Land-Based |
WA1 |
Hanging
scaffolding |
Land-Based |
WA1 |
Footbridge
construction |
Land-Based |
WA1 |
Roof
cladding |
Land-Based |
WA1 |
Refuse collection point |
Land-Based |
WA1 |
Southern
toilet |
Land-Based |
WA1 |
MISC steelwork |
Land-Based |
WA1 |
Lift
installation |
Land-Based |
WA1 |
Escalator
installation |
Land-Based |
WA1 |
Glazed
lift installation |
Land-Based |
WA1 |
Road and
Kerbing |
Land-Based |
NIL |
NIL |
Marine-Based |